587 research outputs found

    Cross-case knowledge transfer in transformative research: enabling learning in and across sustainability-oriented labs through case reporting

    Get PDF
    The field of transdisciplinary sustainability research has brought forward a number of approaches aimed at fostering sustainability transformations and generating knowledge through collaborative experimentation in real-world settings. These cases are strongly embedded in their local context and thus the transfer of knowledge remains a key challenge. In this paper, we propose a case reporting approach that supports the structured and coherent reporting of such cases. This scheme is aimed at sustainability-oriented labs, where sustainability solutions are collaboratively developed through experimentation. The scheme focuses the reporting on local contexts, lab processes, and experiments. It is accompanied by a logic model and a set of four principles guiding the reporting procedure. The approach is designed to be general, in that it is applicable to diverse contexts and project designs, while its modularity allows the scheme to be adapted to the needs and specifics of each cases. The scheme was jointly developed and tested by a group of seven Urban Living Labs, each in their own unique context. With our approach we aim to contribute to knowledge transfer from and across cases of sustainability-oriented labs as emerging approaches in action-oriented research bridging the divide of case-based research and (meta) comparison

    Reactive Chlorine Species Reversibly Inhibit DnaB Protein Splicing in Mycobacteria

    Get PDF
    Intervening proteins, or inteins, are mobile genetic elements that are translated within host polypeptides and removed at the protein level by splicing. In protein splicing, a self-mediated reaction removes the intein, leaving a peptide bond in place. While protein splicing can proceed in the absence of external cofactors, several examples of conditional protein splicing (CPS) have emerged. In CPS, the rate and accuracy of splicing are highly dependent on environmental conditions. Because the activity of the intein-containing host protein is compromised prior to splicing and inteins are highly abundant in the microbial world, CPS represents an emerging form of posttranslational regulation that is potentially widespread in microbes. Reactive chlorine species (RCS) are highly potent oxidants encountered by bacteria in a variety of natural environments, including within cells of the mammalian innate immune system. Here, we demonstrate that two naturally occurring RCS, namely, hypochlorous acid (the active compound in bleach) and N-chlorotaurine, can reversibly block splicing of DnaB inteins from Mycobacterium leprae and Mycobacterium smegmatis in vitro. Further, using a reporter that monitors DnaB intein activity within M. smegmatis, we show that DnaB protein splicing is inhibited by RCS in the native host. DnaB, an essential replicative helicase, is the most common intein-housing protein in bacteria. These results add to the growing list of environmental conditions that are relevant to the survival of the intein-containing host and influence protein splicing, as well as suggesting a novel mycobacterial response to RCS. We propose a model in which DnaB splicing, and therefore replication, is paused when these mycobacteria encounter RCS

    Adaptive optics in the mouse eye: wavefront sensing based vs. image-guided aberration correction

    Get PDF
    Adaptive Optics (AO) is required to achieve diffraction limited resolution in many real-life imaging applications in biology and medicine. AO is essential to guarantee high fidelity visualization of cellular structures for retinal imaging by correcting ocular aberrations. Aberration correction for mouse retinal imaging by direct wavefront measurement has been demonstrated with great success. However, for mouse eyes, the performance of the wavefront sensor (WFS) based AO can be limited by several factors including non-common path errors, wavefront reconstruction errors. and an ill-defined reference plane. Image-based AO can avoid these issues at the cost of algorithmic execution time. Furthermore, image-based approaches can provide improvements to compactness, accessibility, and even the performance of AO systems. Here, we demonstrate the ability of image-based AO to provide comparable aberration correction and image resolution to the conventional Shack-Hartmann WFS-based AO approach. The residual wavefront error of the mouse eye was monitored during a wavefront sensorless optimization to allow comparison with classical AO. This also allowed us to improve the performance of our AO system for small animal retinal imaging. (C) 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreemen

    Effect of a contact lens on mouse retinal in vivo imaging: Effective focal length changes and monochromatic aberrations

    Get PDF
    For in vivo mouse retinal imaging, especially with Adaptive Optics instruments, application of a contact lens is desirable, as it allows maintenance of cornea hydration and helps to prevent cataract formation during lengthy imaging sessions. However, since the refractive elements of the eye (cornea and lens) serve as the objective for most in vivo retinal imaging systems, the use of a contact lens, even with 0 Dpt. refractive power, can alter the system's optical properties. In this investigation we examined the effective focal length change and the aberrations that arise from use of a contact lens. First, focal length changes were simulated with a Zemax mouse eye model. Then ocular aberrations with and without a 0 Dpt. contact lens were measured with a Shack-Hartmann wavefront sensor (SHWS) in a customized AO-SLO system. Total RMS wavefront errors were measured for two groups of mice (14-month, and 2.5-month-old), decomposed into 66 Zernike aberration terms, and compared. These data revealed that vertical coma and spherical aberrations were increased with use of a contact lens in our system. Based on the ocular wavefront data we evaluated the effect of the contact lens on the imaging system performance as a function of the pupil size. Both RMS error and Strehl ratios were quantified for the two groups of mice, with and without contact lenses, and for different input beam sizes. These results provide information for determining optimum pupil size for retinal imaging without adaptive optics, and raise critical issues for design of mouse optical imaging systems that incorporate contact lenses

    At-line validation of optical coherence tomography as in-line/at-line coating thickness measurement method

    Get PDF
    Optical Coherence Tomography (OCT) is a promising technology for monitoring of pharmaceutical coating processes. However, the pharmaceutical development and manufacturing require a periodic validation of the sensor's accuracy. For this purpose, we propose polyethylene terephthalate (PET) films as a model system, to periodically validate the measurements during manufacturing. This study proposes a new approach addressing the method validation requirement in the pharmaceutical industry and presents results for complementary methods. The methods investigated include direct measurement of the layer thickness using a micrometer gauge as reference, X-ray micro computed tomography, transmission and reflectance terahertz pulsed imaging, as well as 1D- and 3D-OCT. To quantify the significance of OCT for pharmaceutical coatings, we compared the OCT results for commercial Thrombo ASS and Pantoloc tablets with direct measurements of coating thickness via light microscopy of microtome cuts. The results of both methods correlate very well, indicating high intra- and inter-tablet variations in the coating thickness for the commercial tablets. The light microscopy average measured coating thickness of Thrombo ASS (Pantoloc) was 71.0 ”m (83.7 ”m), with an inter-coating variability of 8.7 ”m (6.5 ”m) and an intra-coating variability of 2.3 ”m to 9.4 ”m (2.1 ”m to 6.7 ”m)
    • 

    corecore